Key Words:
Frequency,to,Voltage,Converter§,Frequency,to,Voltage,Module§,F,V,Conversion,Module§,Frequency,to,Voltage,Module§,F/V,Converter
Features:
1、Convert the 0-200Hz frequency pulse signal into an analog voltage signal of 0-5V. 2、Can be used to Convert interface between PLC and frequency, Or movement control card and converter interface matching control occasions. 3、Input pulse level is 5V 12V 24V can be directly input, no string resistor. However, the input signal frequency should be maintained for more than 0.5 seconds. 4、The output current is 5MA. 5、Frequency and voltage conversion module, response time is about 0.3-0.5 seconds.
Specification:
Features:
2. Can be used to Convert interface between PLC and frequency, Or movement control card and converter interface matching control occasions.
3. Input pulse level is 5V 12V 24V can be directly input, no string resistor. However, the input signal frequency should be maintained for more than 0.5 seconds.
4. The output current is 5MA.
Specification:
Condition: 100% Brand New
Model: FV-200Hz5V
Function: Input 0-200Hz frequency is converted to 0-5V
Output Current: 5MA
Response Time: 0.3-0.5 seconds
Size: Approx. 4.5 x 4.7 x 1.7cm / 1.8 x 1.9 x 0.7in
Package List:
Precautions for use:
3. The signal input is isolated by diaphragm. Guaranteed anti-interference ability.
4. For use with PLC, support NPN type. Must have a ground wire.
5. If you need to use an encoder, the encoder should be rotated at a constant speed for more than 0.5 seconds.
7. If the signal input is turbine flow, etc., due to signal matching, an 817 diaphragm and a resistor must be added to match the flowmeter to normal function.
8. When using the correspondence, if there is a deviation, you can adjust the blue potentiometer on the board to adjust. At the time of shipment, we have adjusted the F/V potentiometer to a certain correspondence. It is generally not recommended to adjust it by itself.
Identification and wiring:
1. 12-30V--Power input positive
2. GND--Power input negative (common ground wire)
3. GND--Pulse frequency input negative (common ground wire)
4. 0-10KHZ--Pulse frequency input positive
5. GND--Pulse frequency input negative (common ground wire)
6. 0-10V-- Analog 0-10V level output
Correspondence & Linear Relationship:
20Hz is converted to 0.5V
100Hz is converted to 2.5V
200Hz is converted to 5V
Product Image: